Building services · heating, cooling & rooms

Understand buildings.
Room for insight.

Compare temperature histories on heating and cooling pipes and in rooms. Gain a better understanding of operating times, comfort and changes in everyday building use.

Heating, cooling & roomsExample
Example · room temperature21.6 °C
Time historyTemperature

Illustrative example with fictional readings.

Typical applications

Where data
provides insight.

Reveal temperature patterns over time in buildings.

01

Heating and cooling pipes

Review surface temperature histories at selected pipe measurement points.

02

Room temperatures

Understand differences between rooms and between daytime and night-time operation.

03

Technical investigation

Use measurement series before and after an adjustment to observe the change at the measurement point.

Time series rather than guesswork.

When does a room get warmer? How does pipe temperature change throughout the day? Comparable measurement points can reveal relationships over time. Interpretation takes account of usage, weather and system operation.

Data as a basis for decisions.

Temperature data can support technical analysis. On its own, it does not prove energy savings. Such an assessment also requires, for example, consumption data and suitable comparison conditions.

For room temperature, the sensor is placed at a representative position away from direct sunlight, heaters and draughts. For pipe temperature, it sits on the pipe surface with suitable thermal contact. The temperature at the sensor is measured in each case: ambient temperature in the room, surface temperature on the pipe.
More about pipe mounting
Matched to the measurement task

Sensor and pipe mounting.

Choose a temperature sensor for continuous transmission or a logger with Backfill. At pipe measurement points, our own mount complements the setup.

Your application. Clearly explained.

Frequently asked questions.

Can I compare room and pipe temperatures?

Yes, the time series can be considered together. However, it must remain clear which quantity and position are being measured in each case. Differences between surface and air temperature must be considered in the evaluation.

Does SmartSensio automatically control my heating?

The logger offered here measures and transmits temperatures. Automatic control requires additional control equipment and suitable integration, which are not part of this logger offering.

Are current remote alarms possible without a connection?

Without a connection, readings initially remain in local memory. Current cloud readings and notifications based on them are unavailable during this period. A continuous warning concept requires reliable online connectivity.

Buildings & rooms

What would you like to measure?

Tell us the installation site, measurement points and desired time period.

Request a suitable quote